Annex - LUTZ B1 BATTERY Manual De Instrucciones

Ocultar thumbs Ver también para B1 BATTERY:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en

Annex

Trouble shooting
Fault
The motor does not start
when switched on.
When switched on, the
motor does not start and
the on/off switch starts to
flash.
When the speed increases,
the motor stops and the on/
off switch starts to flash.
16
Cause
Motor is in sleep mode
(downtime longer than
2 minutes).
Battery voltage too low.
Density or viscosity of the
pumped liquid is too high.
Pump tube blocks or stiffs, there-
fore an excessively high torque
occurs and the motor automati-
cally switches off.
Load too high
Observe operating limits
with regard to pump tube
combination and viscosity/
density (→ Operating
instructions pump tube).
Remedy
Press on/off switch twice
Charge battery
Check operating limits
→ Operating instructions pump
tube
If necessary, reduce motor speed.
Disconnect pump tube from mo-
tor and turn on the coupling.
Result:
Stiff → repair pump
Smooth-running → repair motor
Reduce the speed and acknowl-
edge the error. Then work with a
reduced flow rate.
Tabla de contenido
loading

Este manual también es adecuado para:

B2 battery0001-1150002-515

Tabla de contenido