Health Zenith SL-4190 Serie Manual De Usario página 2

Farol de fundición con detector de movimiento
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION
For best performance, mount the fixture about
6 feet (1.8 m) above the ground.
WARNING:Turn power off at the circuit
breaker or fuse.
1. Remove
two nuts.
3. Tighten screws
finger tight.
5. Attach X-Bar to
junction box
Due to the size and weight of the fixture, you
may find it helpful to have an assistant hold the
fixture in place while connecting the wires.
2. Remove
X-Bar.
SENSITIVITY
MIN
MAX
4. Set sensitivity on
fixture back to the
mid-position.
Junction
Box
WIRING
WHITE
One Motion Light
BLACK
WHITE
Two Motion Lights
❒ Twist the junction box wires and the
fixture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green "pigtail". If you are unsure about
the grounding method, consult your local
building code.
CAUTION: DO NOT connect the RED
wire unless you want to control other
lights from the motion sensor.
Recommended Grounding Method
Use a green ground "pigtail" (not provided) and
twist one end together with the bare fixture wire
and the box ground wire. Secure with a wire
connector. Secure the other end of the "pigtail"
with the GND screw on the X-bar.
Black to black
2
BLACK
BLACK
White to white
595-5628-07