PARAMETER VALUE
vEL.A
hi
Lo
vEL.C
hi
Lo
P.APP
0 - 100
St.cF
Strt
oPEn
St.AP
PAUS
no
ChiU
St.Ch
Stop
APEr
St.PA
ChiU
no
PAUS
SEn.A
no
1-9
SEn.C
no
1-9
DESCRIPTION
Opening speed (only ATRIS1000)
WARNING: It is necessary to perform the force self-learning
SEn
(
menu) each time the value of this parameter is modified.
High speed (20 cm/s)
Low speed (12 cm/s)
Closing speed (only ATRIS1000)
WARNING: It is necessary to perform the force self-learning
SEn
(
menu) each time the value of this parameter is modified.
High speed (20 cm/s)
ATTENTION: If the level of protection type C (table chap. 1.1), if
the closure speed is set to a higher value (Atris1000 only), you are
advised to use a sensitive edge.
Low speed (12 cm/s)
Partial opening percentage
Percentage of travel the door performs when a partial opening command is
received.
NOTE: Partial opening can only be controlled by radio via channel 2 of the
receiver.
Use of the START input
Start function (also linked to parameters
Opening function (Open-Stop)
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
The door stops and goes to pause
The START command is ignored
The door immediately starts closing
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
The door stops and the cycle ends
The door opens again
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a Start
command when the door is open during its pause phase
The door recloses
The START command is ignored
The pause time is reset (if the parameter
given during the pause enables the gate closing phase)
Sensitivity of the obstacles sensor during the opening phase
Function deactivated
1: maximum sensitivity
9: minimum sensitivity
Sensitivity of the obstacles sensor during the closing phase
Function deactivated
1: maximum sensitivity
9: minimum sensitivity
St.AP, St.PA, St.Ch
Ch.AU
no
=
, a START command
- 41 -
DEFAULT
MEMO
hi
Lo
20
Strt
PAUS
StoP
ChiU
3
3