In Case Of Difficulty; Specifications - DART Controls 125D Serie Manual Del Usuario

Ocultar thumbs Ver también para 125D Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROBLEM
Motor doesn't operate
Armature output voltage
cannot be adjusted, output
is a constant DC level
Motor stalls, or runs
very slowly with speed
control turned fully CW
Motor hunts
Repeated fuse blowing
If control still will not operate, consult your Dart Distributor or Representative.
AC input voltage .................................................................................................................................. ±10% of rated line voltage
Acceleration ..................................................................................................................................... 0.5 seconds (standard 125D)
Amps - DC output .......................................................................................................................................... 150 mA to 5.5 ADC*
Controller overload capacity ......................................................................................................................... 200% for one minute
Current limit trimpot range ........................................................................ 0.3 to 2.5 ADC (125D); 1 to 15 ADC (123D & 125DV)
Deceleration .................................................................................................................................... 0.5 seconds (standard 125D)
Dimensions and weights:
Drive service factor ................................................................................................................................................................... 1.0
Effi ciency ..................................................................................................................................................................... 85% typical
Input frequency ....................................................................................................................................................... 50 or 60 Hertz
Max. trimpot speed range ................................................................................................................. 60% to 110% of base speed
Min. trimpot speed range .............................................................................................................. 0% to 30% of maximum speed
Power devices ..................................................................................................................................................... isolated case tab
Shunt fi eld voltage ........................................................................................... 20VDC for 24VAC input; 30VDC for 36VAC input;
Shunt fi eld voltage ........................................................
Speed control .................................................................................. via 5Kohms 2W potentiometer or 0-10VDC isolated signal
Speed range ........................................................................................................................................................................... 50:1
Speed regulation ............................................................................................................................................ ±1% of base speed
Temperature range ............................................................................................................. -10
Transient protection ......................................................................................................................................................... G-Mov**
Trigger ........................................................................................................................................................................ opto-coupler
Type ramp of accel/decel ................................................................................................................................... RC time constant
* With -HS(125D) or suitable external heatsink (where 125D extrusion temperature does not exceed 70° C.), maximum U.L.
rating for output amps can be increased to 10 amps D.C.
** not used on the 123D-C series control

IN CASE OF DIFFICULTY

POSSIBLE CAUSE(S)
- Blown Fuse
- Incorrect or no power source
- Speedpot set at Zero
- Worn motor brushes
- No motor or load connected
- Speedpot low connection open
- Low Voltage
- Overload Condition
- Worn motor brushes
- MAX SPEED set incorrectly
- Motor current less than 150mA
- Too much IR COMP
- Motor is in current limit
- Motor speed is above rated speed
- Max set too high
- Low Voltage
- Overload Condition
- Worn motor brushes
- Defective motor bearings
- Defective electrical components

SPECIFICATIONS

WIDTH
LENGTH
ENGLISH
3.625"
METRIC
92mm
100VDC for 120VAC input; 200VDC for 240VAC input; 1 amp maximum
CORRECTIVE ACTION(S)
Replace Fuse
Install proper service
Adjust Speedpot CW to start
Replace brushes
Check that motor or load is connected
to armature terminals
Check that speedpot low wire is connected
Check-should be above 100V or 208 V
Reduce load
Replace brushes
See ADJUSTMENT PROCEDURE
Motor current must be greater than 150mA D.C.
See ADJUSTMENT PROCEDURE
See ADJUSTMENT PROCEDURE
Reduce Speed
See ADJUSTMENT PROCEDURE
Check-should be above 100V or 208V
Reduce load
Replace
Replace
Call Dart Distributor or Representative
DEPTH
WEIGHT
4.250"
1.300"
8.00 oz.
108mm
33mm
228 gms.
11
o
to 45
o
C. ambient (15
o
to 115
o
F.)
Tabla de contenido
loading

Este manual también es adecuado para:

123d-c125d-12c125dv-c

Tabla de contenido