Troubleshooting - Zanussi ZWT 71401 WA Manual De Instrucciones

Ocultar thumbs Ver también para ZWT 71401 WA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Screw the hose back onto the tap. Make sure
the connection is tight.
45°
20°
Frost precautions
If the appliance is installed in an area where the
temperature can be less than 0° C, remove the
remaining water from the inlet hose and the
drain pump.
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. Place the end of the emergency emptying
hose and that of the inlet hose in a bowl

Troubleshooting

WARNING!
Refer to Safety chapters.
Introduction
The start of the appliance does not occur or it
stops during operation.
First try to find a solution to the problem (refer
to the table). If not, contact the Authorised
Service Centre.
www.zanussi.com
Unscrew the hose
from the machine.
Keep a rag nearby
because some water
may flow.
Clean the filter in the
valve with a stiff brush
or with the piece of
cloth.
Screw the hose back
to the machine and
make sure the
connection is tight.
Turn on the water tap.
placed on the floor and let water flow out of
the hoses.
4. Set the Drain programme and let it operate
until the end of the cycle.
5. Turn the programme knob to
disconnect the appliance from the power
supply.
6. Screw the water inlet hose back on and re-
fit the emergency emptying hose after
having put the cap on again.
WARNING!
Make sure that the temperature is
more than 0 °C before you use the
appliance again. The manufacturer is
not responsible for damages caused
by low temperatures.
Frost precautions
If the appliance does not drain the water,
proceed as follows:
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. if necessary, wait until the water has cooled
down.
4. Place a bowl on the floor and put the end of
the emergency emptying hose into the
bowl. Remove its cap.
The water should drain by gravity into the bowl.
5. When the bowl is full, put the cap back on
the emergency hose.
6. Empty the bowl. Repeat the procedure until
water stops flowing out.
7. Clean the pump if necessary as previously
described.
8. Replace the emergency emptying hose in
its seat after having plugged it.
9. Screw the water inlet hose back on.
With some problems, the acoustic signals
operate and the display shows an alarm
code:
- The appliance does not fill with water
properly.
- The appliance does not drain the
water.
to
19

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido