MAINTENANCE:
Mito was designed to minimize maintenance. The following instructions must be closely followed to
guarantee trouble free operation of the device for a long time:
- Do not allow the device to reach temperatures below 3 °C; if this is not possible, make sure that all the
water present in the device has been drained to avoid any damage to the plastic housing in case of
freezing.
- If the pump is fitted with suction filters, periodically check that they are clean.
- Always make sure that the cover is completely closed to avoid infiltration of water from outside.
- During long periods of system inactivity, disconnect from power supply and drain the water from the
system.
- Avoid forcing pump operation when there is no water intake; this could damage both the pump and
Mito.
- Before using the device with liquids other than water, check with the manufacturer.
- Never operate the device without the covers in place.
- Before removing the cover of the device wait 3 minutes to allow the capacitors to discharge.
WARNING: The device does not contain any user serviceable parts. We recommend against
removing the protective cover of the circuit board as this will void the warranty and could be
dangerous.
Installation Date
Client
Pump Brand-Model
Serial No. Mito
VALUES SET DURING INSTALLATION
Pmax:
DeltaP
Stop Delay
Auto-Reset Time
Auto-Reset Test
Note
.... / .... / ....... Installer
Bar
Bar
Bar
Seconds
Minutes
N° test
29