INSTALLATION
HYDRAULIC CONNECTION:
Mito must be installed on the pump' s output, in horizontal or vertical position, with the direction of flow
as indicated by the arrow on the cover. The water from the pump flows through the device to then be
distributed to the various users.
Water supplied to Mito must not have impurities or other contamination which could block the movement
of the check valve located inside. To minimize this problem it is helpful to mount specific filters on the
intake of the pump.
Install a small expansion vessel (1-2 litres) after Mito. This limits restarts caused by possible small
p r e s s u r e f l u c t u a t i o n s i n t h e s y s t e m a n d i m p r o v e s t h e s y s t e m ' s r e s p o n s e t o s m a l l d e m a n d s o f w a t e r f r o m
the system (i.e. washing machines, toilet flushing systems, etc.).
The pre-charge value of the vessel must be suitable for the pressure values set.
It is absolutely imperative that no check valve be installed between Mito and the electric pump or between
the actual device and the users, since this can cause malfunctions of the device.
A check valve may be installed in the suction pipe of the electric pump to avoid emptying at shut-off.
We advise against installing the device inside wells or sealed boxes where a heavy condensation could
develop.
WARNING: when the pump stops the pipes are still under pressure. Before any intervention it is
advisable to discharge the system by opening a tap.
CAUTION: this device is not to be considered a mechanical pressure reducer and therefore all
system parts must be sized according to the maximum supply pressure of the pump.
WIRING:
Insert the electric cables into the specific cable glands in the correct order
of assembly of all the components. Tighten the gland nuts sufficiently
to prevent movement of the cables.
The central cable gland for the auxiliary contact is blind: if you want to insert a
cable for remote control, the bottom of the plastic nut must be broken through with a
screwdriver after removing the nut from the unit.
The electrical connectors supplied with the device must be used.
WARNING: Insert the connectors so that the fastening screws of the cable are not adjacent to each
other!
CORRECT
WRONG
21