INSTALLATION
For under eave installation, the sensor head
must be rotated as shown in the next two steps
for proper operation and to avoid the risk of elec-
trical shock.
For eave mount only:
1. Swing the sensor head towards the clamp
screw.
Clamp Screw
2. Rotate the sensor head clockwise 180° so
the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the
ball joint. Tighten the clamp screw when done.
These instructions show the sensor wired to flood
lamps.The white sensor wire is neutral.The black
sensor wire is hot. The red wire is the switched
"hot" wire. The lighting load (500 W, 4.2A max) is
placed across the white and red wires.
1. Remove the existing light fixture, if present.
2. After screwing the sensor into the wall plate,
Controls
Controls
1. Follow the instructions that came with your light
2. Keep regular PAR-38 lamps at least 1" (25 mm)
-2-
Wire the Light Control
WARNING: Turn power off at the fuse or
circuit breaker.
connect the junction box wires to the light control
wires by twisting together and securing with wire
connectors.
White to White
Junction
Box
Black to Black
Optional: Connect additional load
across the white and red wires. Total
lighting load including lamp heads on
fixture must not exceed 500W (4.2A).
Mount the Light
fixture for mounting and adjusting the light fix-
ture.
from the sensor. Halogen lamps should be kept
at least 2" (51 mm) from the sensor.
Red Sensor Wire to
Black Lamp Wire
Lamp
Holders
206443-01