8. Specifications
Differential pressure gauge Eco, model A2G-05
Version
Nominal size in mm
Measuring range
Unit
Scale
Accuracy class
Span ≥ 250 Pa
Span 101 ... 249 Pa
Span ≤ 100 Pa
Process connection
Movement
Materials
Case components
Separating diaphragm
Window
Dial
Pointer
Mark pointer
Medium
Permissible temperatures
Medium
Ambient
Max. working pressure (static pressure)
Ingress protection per IEC/EN 60529
Weight (pressure measuring system)
WIKA operating instructions, model A2G-05
Standard version
■
Silicone-free version
■
110
0 ... 100 Pa to 0 ... 6,000 Pa
■
-50 ... +50 Pa to -1,500 ... +1,500 Pa
■
Other plus/minus ranges on request
Pa
■
kPa
■
inWC
■
mmWC
■
mbar
■
Single scale
■
Dual scale
■
3.0
5.0
10.0
Fixed connection in angular form for hoses with
inner diameter 4 ... 6 mm
Contact-free transmission (SWISS MOVEMENT)
Plastic, glass-fibre reinforced
Silicone
■
EPDM (with silicone-free version)
■
Polycarbonate (UV stabilised)
Aluminium
Plastic, black
Without
■
Plastic, red
■
Air
■
Non-flammable and non-aggressive gases
■
-20 ... +50 °C [-4 ... +122 °F]
-30 ... +80 °C [-22 ... +176 °F]
20 kPa
IP54
■
IP65
■
240 g
EN
13