REMOTE CONTROL MEMORY STORAGE
(FIG.3)
Up to 30 different channels can be stored on each control unit.
The button SW1 is used to start the data saving procedure in the
desired DEV-R1 module.
Follow the steps outlined in the specific paragraphs.
L1 - the led lights up when you press the SW1 button to store or
clear transmitters
L2 - the led lights up when the DEV-R1 module receives a code
which is stored in the memory
MEMORY CLEARING BY MEANS OF BUTTON
SW1
This procedure enables to clear all the transmitters stored in the
DEV-R1 module.
Proceed as follows:
1. Switch off the DEV-R1 module
2. Hold the button SW1 and at the same time switch on the
DEV-R1 module
3. After 2 seconds, release the button SW1: the motor confirms
successful clearing by moving in both directions for half a
second
PROTEO SERIES TRANSMITTERS STORAGE
PROCEDURE (FIG.4)
m
WARNING: the first transmitter stored fixes the direction of
motion of the motor.
To store a transmitter TX1 on a blank control unit proceed
as follows:
1. Power only the control unit to be programmed
2. Set on ON the switch 1 of the transmitter.
3. Multichannel transmiter only: press several times the key SELC
of the transmitter TX1 until displayed the selected channel (by
the leds or on the display).
4. Press and keep pressed (for about 5 seconds) the key PROG of
the transmitter TX1 until the motor starts to move in one way.
5. Release the key PROG: the motor stops.
6. Press the keys UP or DOWN depending on the way of motion
of the roll-up shutter before stopping:
-
if the roll-up shutter was going up, press the key UP;
direction acquired: the key UP moves the roll-up shutter
UPWARDS, the key DOWN moves the roll-up shutter
DOWNWARDS.
-
if the roll-up shutter was going down, press the key
DOWN; direction acquired: the key DOWN moves the roll-up
shutter DOWNWARDS, the key UP moves the roll-up shutter
UPWARDS.
7. Set the switch 1 to OFF.
8. Try to operate the roll-up shutter and check that it works with
the logic above described. If the logic is reversed, it is necessary
to delete all the codes stored (read Switch 3) and start again
the above procedure.
To add another transmitter TX2 to the control unit it is
necessary to use a remote control previously stored (TX1)
and proceed as follows:
1. Multichannel transmiter only: press several times the key SELC
of the transmitter TX1 until displayed the channel stored (by
the leds).
2. Multichannel transmiter only: press several times the key SELC
of the new transmitter TX2 until display the channel to be
stored (by the leds).
3. Take the roll-up shutter to half its way with TX1.
4. Set to ON the switch 1 of the transmitter TX1.
5. Press and keep pressed for about 5 seconds the key PROG of
the TX1 until the motor starts to move.
6. Release the key PROG, the motor stops.
7. Press the key UP or DOWN of the TX2: the transmitter is stored
with the same logic of the TX1.
DELETION OF ALL THE STORED
TRANSMITTERS WITH PROTEO TRANSMITTER
To delete all the transmitters stored on the control unit it
is necessary using a remote control previously stored and
proceed as follows:
1. Power only the control unit to be programmed
2. Multichannel transmiter only: press several times the button
SELC on the transmitter until displayed the channel stored
(by the leds)
3. Position the roll-up shutter at the mid-height.
4. Set on ON the switch 3 of the transmitter.
5. Press and keep pressed the button PROG of the transmitter
until the motor moves in both the ways for 1 second, showing
the end of deletion.
6. Release the button PROG and set on OFF the switch 3 of the
transmitter.
To delete all the codes by means of a transmitter non-
stored, proceed as follows:
1. Position the retractable at the mid-height.
2. Switch off power supply of the system.
3. Set on ON the switch 3 of a transmitter.
4. Press and keep pressed the button PROG.
5. Supply power only to the control unit on which to make the
deletion: after about 1 second the motor moves in both the
ways showing the correct deletion.
6. Release the button PROG and set on OFF the switch 3.
- 8 -