DESCRIPTION
The DEV-R1 module allows to control a single phase asynchronous
motor for the automation of awnings and rolling shutters.
The small size of the container allows the module to be easily
inserted inside the switches.
• Power supply with extended range: 85 ÷ 260 Vac - 50/60 Hz
• 434.15 MHz radio receiver with integrated antenna
• Compatible with PROTEO, ARTEMIS and DEV-T1 transmitters
• Stores up to 30 radio channels
• Two wired inputs: up and down
• Output to control a single phase asynchronous motor
• Integrated button for programming operations
• Wireless programming via a remote control provided with
memory
• Wireless management of HURRICANE-RS, TYPHOON and
SYROCO-RS series weather sensors.
SPECIFICATIONS
Power supply ______________________ 85 ÷ 260 Vac - 50/60 Hz
Consumption in stand-by ____________ 0,25 W
Motor maximum power _____________ 500 W
Operating temperature ______________ -20 ÷ +60 °C
Maximum operating time____________ 120 s
Protection _________________________ IP10
IMPORTANT REMARKS
• Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
• Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
• This device can be installed only from qualified persons.
• The control buttons and the connection cables shall have
insulation properties suitable for electrical installations with
operating voltage of not less than 300Vac
• In order to protect the device, the installer must provide for
a magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
• The device must be installed only inside a junction box or wall
box.
• The device container does not provide any protection
against water. Thus, it should be installed only in protected
environments.
EU DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that DEV-R1 products conform to the
essential requirements established in the following directives:
- 2014/30/UE (EMC Directive)
- 2014/35/UE (Low Voltage Directive)
- 99/05/CEE (Radio Directive)
- ROHS2 2011/65/CE
Racconigi, lì 01/06/2019
V2 S.p.A. legal representative
Sergio Biancheri
WIRING (FIG.2)
p
Salita motore
q
Discesa motore
COM
Comune motore
P1
Ingresso pulsante P1 (comando di salita)
P2
Ingresso pulsante P2 (comando di discesa)
N
Neutro alimentazione
L
Fase alimentazione
NOTA: la direzione del motore (salita/discesa) dipende dalla
posizione del motore e dai collegamenti effettuati.
WIRED INPUTS OPERATING LOGIC
The two wired inputs (P1 and P2) work with HOLD TO RUN logic:
the motor moves up or down as long as the button is pressed.
The motor direction (up/down) depends on the position of the
motor and wiring.
NOTE: during the movement of the motor, if the second
button is pressed, the motor reverses the motion.
TRANSMITTER OPERATING LOGIC
The wireless controls via transmitter operate with UP-DOWN
logic.
Each time the buttons are pressed, the operating logic will be as
follows:
a
UP:
CLOSES
a
STOP:
STOPS
STOPS
a
DOWN:
OPENS
OPENS
SENSOR ACTIVATION
To activate the sensors function, at least one transmitter must be
stored.
NOTE: the HURRICANE RS and TYPHOON sensors use one
channel in the memory of the DEV-R1 module
m
IMPORTANT:
• Anemometer causes inhibition of functioning of both radio
transmitter and external push button for ca. 8 minutes.
• The anemometrical sensor should be installed close to the
awnings, in order to avoid damages in case of very strong
wind.