16.1 - MAINTENANCE SCHEDULE

Description of the activity
Tightening the electrical terminals
Tightening ground anchoring nuts
Cleaning the front
Cleaning the fan filter
Cleaning the Retractor (only for exit sta-
tion)
Cleaning the printer (only for entry station) every 8000 tick-
Checking the fan operation
Checking the anti-condensation resistor
operation
Detector loop sensor reset
Check of the ticket quality if the station
has been inactive for some time
Frequency
Type of action
yearly
tightening with tool
yearly
tightening with tool
monthly
washing with water
monthly
blowing with compressed air
monthly
blowing with compressed air and
electrostatic cloth
blowing with compressed air and
ets or every six
electrostatic cloth
months
monthly
visual check
every six
check with contact and temperature
months
sensor
monthly
reset button pressure
monthly
visual and contact check