Elvox 6600 Serie Manual Para El Conexionado Y El Uso página 8

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
GB
VIDEO SIGNAL STABILISATION
On the rear of monitor type 6611 and 6711
there are some connectors (A-B-C) for the
video signal stabilization.
For the table version monitors type 661C the
video signal stabilization is carried out by
means of a jumper on terminal block A-B-C
present on the stud. For types 6611, 6711 and
661C this jumper must be used in installations
with several appliances (interphones and mo-
nitors) connected in series (Fig. 3).
In series configuration displace the jumper (only
in the last set) into "B" position and keep the
jumpers of other interphones or monitors in the
initial position, i.e. "A" (Fig. 3).
For other wiring configurations see note: "Bus
termination for ELVOX TWO-WIRE installations"
provided below, in the wiring diagrams section.
P R O G R A M M I N G / O P E R A T I O N
B
A
A
A
Fig. 3
Art. 6611
Art. 6711
Art. 661C
PROGRAMMING
There are three monitor programming modes: assignment of an identification
code or call code (indispensable), assignment of a secondary identification
code (for video interphones associated with a master video interphone), pro-
gramming of push-buttons for auxiliary services and intercommunicating calls
(when necessary).
Programming must be performed with the system switched on, without ac-
tive communication and only after connecting the interphones/video inter-
phones to the system and programming the panels.
Programming the identification code
The identification code is to be programmed by means of an entrance panel
(main- "Master"), present on the installation and already configurated. The
video-interphone is supplied without associated identification code. To check
this, press the "G" push-button and the video-interphone will emit a triple
"Beep".
Attention: during the interphone/video interphone identification code
programming you have 30 seconds from the moment you enter the pro-
gramming in the interphone/video interphone and the moment you press
the call push-button on the panel or you send the code.
Programming phase:
1)
Press and hold down "I".
2)
Press and hold down also "H" together with "I".
3)
Wait for nearly 3 seconds until the red led "M" flashes.
4)
Now the microprocessor is physically reset.
5)
Release both push-buttons "I" and "H". You have now 5 seconds to carry
out any of the described programmings.
6)
Press and hold down the "G" lock push-button.
7)
After nearly 2 seconds the video-interphone emits a high-pitched tone, it
self-starts and gets in communication with the entrance panel.
8)
On the entrance panels with push-buttons press the call push-button
corresponding to the video-interphone, on the alphanumeric entrance
panel, on the contrary, enter the call code and press "
9)
If on the installation there is already an interphone / video-interphone with the
same associated identification code, the panel emits a low-pitched tone and
you must repeat the operation from the beginning.
10) If not, the code is associated to the video-interphone and the communi-
cation is terminated.
Programming the secondary identification code
The programming of the secondary identification code is required only when
you want more than a video- interphone to ring at the same time with the
same push-button or call code. The video-interphones which must ring si-
multaneously are associated with the same push-button to the same group.
The "master" interphone / video-interphone is programmed in first place by
means of the previous procedure: "programming the identification code". The
additional interphones / video-interphones are programmed with the secon-
dary identification code (see table shown in the wiring diagram section enclo-
sed with the electronic TWO WIRE ELVOX entrance panels). A maximum of
three audio door entry units plus one group master can be associated with the
same group, without the need for programmer Type 950C or SaveProg.
Programming phase:
1)
Press and hold down "I".
2)
Press and hold down also "H" together with "I".
3)
Wait for nearly 3 seconds until the red led "M" flashes.
4)
Now the microprocessor is physically reset.
5)
Release both push-buttons "I" and "H"
6)
Press and hold down the "G" door lock and the "H" self-start push-but-
tons simultaneously.
7)
After 2 seconds the video-interphone emits a high-pitched tone and gets
in communication with the entrance panel.
8)
Release the door lock "G" and the self-start "G" push-buttons.
9)
On the push-buttons entrance panels press the call push-button corre-
sponding to the main (already programmed) interphone / video-inter-
phone, on the alphanumeric entrance panel, on the contrary, enter the
same call code of the "Master" interphone / video-interphone and press
"
".
10) If on the installation there is already an interphone / video-interphone with the
same associated identification code, the panel emits a low-pitched tone and
you must repeat the operation from the beginning.
11) Once the secondary identification code is associated to the video-inter-
phone, the communication is terminated.
To know the number assigned see table shown in the wiring diagram section.
8/32
".
loading