Alarm Function - V2 EASY-LUX Manual Del Usuario

Cuadro de maniobras digital para persianas enrollables
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
INPUTS
oFF
DISPLAY
in 1
PHOTOCELL ACTIVE ONLY DURING
CLOSING
The intervention of the photocell during
the opening stage is ignored.
The intervention of the photocell during
the closing stage causes the shutter to
reopen.
in 2
PHOTOCELL TEST INACTIVE
The photocell operation test is not
performed
in 3
MECHANICAL SAFETY EDGE
The L6 input is configured to manage a
mechanical safety edge
in 4
FIRE FUNCTION
The L7 input is configured to manage a
fire alarm
in 5
EDGE / FIRE FUNCTION
The L6 input is configured to manage a
safety edge
The L7 input is configured to manage
an alarm
in 6
DISABLING OF THE SAFETY EDGE
WHILE CLOSING
Function off
on
PHOTOCELL ACTIVE DURING OPENING AND
CLOSING
The intervention of the photocell during the
opening phase causes the motor to stop.
When the photocell beam is released, the
automation starts during opening for the work
t i1
time set in parameter
.
The intervention of the photocell during the
closing stage causes the shutter to reopen.
PHOTOCELL TEST ACTIVE
Each time the control unit receives an open or
close command, the PHOTOCELL TEST verifies
that the PHOTOCELL is operating correctly.
If the test fails, the display shows
RESISTIVE RUBBER / OPTICAL SAFETY EDGE
The L6 input is configured to manage a safety
edge (resistive rubber / optical) with active
operation test.
If the test fails, the display shows

ALARM FUNCTION

The L7 input is configured to manage an
anti-theft command
LIMIT SWITCH FUNCTION
The L6 input is configured to manage an opening
limit switch
The L6 input is configured to manage a closing
limit switch
in 5
NOTE: If
is set on the settings of the
in 4
and
functions, they are not considered
DISABLING OF THE SAFETY EDGE WHILE
CLOSING
In case of irregular floors, you might have to
disable the safety edge on the last closing section
of the door (max. 5cm) to prevent any unwanted
enabling of the edge.
To set the point at which to disable the edge,
follow the procedure on page 20.
- 17 -
dEF1
dEF2 dEF3 dEF4
on
oFF
oFF
oFF
- L5 -
oFF
on
- L6 -
oFF
oFF
oFF
oFF
in 3
oFF
oFF
oFF
on
oFF
oFF
oFF
oFF
oFF
oFF
oFF
oFF
oFF
oFF