Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slip the slide washer, washer and collar nut
over the hose and threaded base and tighten
the collar nut by hand.
4. Tighten screws.
5. Connect the supply pipes to the isolation
valves;
cold right - hot left.
6. Connect the pull rod to the pop-up waste.
The pressures of the cold and hot water connections
must be balanced.
Operation
The mixer is activated by lifting the lever handle.
Move to the left = hot water,
move to the right = cold water.
Technical Data
This mixer series-produced with water-
dimmer
(flow limiter)
®
Rate of flow with waterdimmer:
Rate of flow without waterdimmer: 14 l/min 0,3 MPa
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Test certificate 31060000:
English
7 l/min 0,3 MPa
max. 1 MPa
1,6 MPa
max. 80° C
65° C
WRAS
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer
(6a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 4)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
seal
6
aerator cpl.
7
fixing set
8
connection hose
9
pop up rod
10
ball joint
11
aerator cpl.
12
connection hose
13
supply pipe
14
connection hose (31060003)
Special accessories
X
special tool set
(not part of delivery)
®
31093000
96338000
97406000
97209000
92730000
95008000
13912000
13961000
96321000
96657000
97362000
97360000
97206000
96638000
97443000
58085000