GENERAL PRODUCT DESCRIPTION
PERFORMANCE DATA
• Function summer / winter
• Luminous signals: Led indicating load on/off
• Remote control input for night-time lowering of heating (winter
lowering is not possible for summer conditioning
• Night time reduction temperature (referring to set): – 4°C
TECHNICAL SPECIFICATIONS
• Power supply:
• Type of disconnection and appliance:
• Type of relay output:
• User connections (load):
• Max. wire section at the terminals:
• Type of insulation:
• Grade of protection:
• Pollution:
• Regulation range:
• Thermal gradient:
• Differential operation:
• Precision of reading:
• Temperature operating limits:
• Reference standards for CE marking:
EMC EN55014-1 EN55014-2 EN61000-3-2 EN61000-3-3
LVD EN60730-1 EN60730-2-9
(Directive 89/336/CEE - 7323/CEE)
F U N C T I O N S
12
). (Night-time
).
230 V~ 50÷60 Hz
1 B / Electronic
with exchange contact
NO/COM/NC 8(2)A / 250 V~
2 or 3 wires
2.5 mm
2
Class II
IP 30
Normal
from +5°C to +30°C
max 1K/15 min.
∆t = 0.7°C
± 1°C
0°C to +50°C