Lighting Mod/Var Ramp RTS-LB1
8.3 Restoring the original confi guration
Caution! This reset deletes all control points and resets the favourite
light intensity level to 50% of the total power.
Caution! Only switch off the power to the Lighting Mod/Var Ramp
RTS-LB1 to be reset!
Caution! Do not use the Inis RT/Inis RTS control point for resetting!
1)
Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the ramp will fl ash slowly.
5)
Press the PROG button on the RTS control point until the ramp
comes on then goes out twice in succession: all control points have
been deleted.
-
Follow the procedures in the section entitled "Commissioning" to add
RTS control points.
8.4 Replacing a lamp
Caution! Never dispose of the lamp with domestic waste. Please take
the lamp to a collection point or an approved centre to ensure that it
is recycled.
1)
Disconnect the power supply and wait for the lamp to cool down
before undertaking any operations.
2)
Unscrew the cover with the protective glass (l) by turning anticlockwise
and remove it.
3)
Remove the refl ector dish (n) from its location using a fl at blade
screwdriver or similar (o).
4)
Pull the refl ective dish (n) upwards to remove the lamp (p) from its
bracket.
-
To fi t a new lamp, replace the refl ective dish (n) and slot the new
lamp into its housing.
Caution! Avoid touching the new lamp with your fi ngers when replacing
the defective lamp.
-
Screw the cover with protective glass (l) back into its housing.
-
Connect the power supply.
9. Technical data
Radio frequency
Power supply
Maximum total power
Index protection rating
Operating temperature
Safety level
40
Number of programmable RTS
433.42 MHz
control points
230 V ~ 50 Hz
Dimensions (mm)
As indicated on
Weight (kg)
product
IP34
Lamp
- 20°C to + 60°C
Life time (hours)
Class I
Copyright © 2008 - 2010 Somfy SAS. All rights reserved.
Installation guide
1
2
OFF
ON
2 sec.
10 sec.
OFF
3
4
ON
2 sec.
5
.
PROG
1
OFF
2
I
3
o
n
4
n
12 maximum
As indicated on
product
As indicated on
product
Osram Halostar
G4, 12 V, 20 W
4000
...