Opening/closing the trigger gun
To open the trigger gun: Actuate the
safety lever and trigger.
To close the hand spray gun: Re-
lease the safety lever and trigger.
High pressure operation
Note:
The appliance is equipped with a pres-
sure switch. The motor starts up only
when the trigger gun is open.
Set the appliance switch to "I".
Release the trigger gun. To do so,
push the safety catch towards the
back.
Open the hand spray gun.
Set the working pressure and quantity
by turning the pressure/ quantity regu-
lation mechanism at the pump unit.
Replace the nozzle
DANGER
Switch the appliance off prior to replac-
ing nozzel and activate hand spray gun
until device is pressureless.
Unscrew nozzle screws and re-
move the nozzle.
Put on a new nozzle.
Screw on the nozzle screws and
tighten them by hand.
Operation with detergent
WARNING
Unsuitable detergents can cause dam-
age to the appliance and to the object
to be cleaned. Use only those deter-
gents that have been approved by
Kärcher. Observe the dosage and oth-
er instructions provided with these de-
tergents. For considerate treatment of
the environment use detergent eco-
nomically.
Follow the safety instructions for using
detergents.
10
Kärcher detergents ensure smooth
functioning. Please consult us or ask
for our catalogue or our detergent in-
formation sheets.
Place the detergent bottle into the
bottle holder on the appliance or
place a detergent container next to
the appliance.. Two different deter-
gents can be simultaneously placed
into the appliance.
Pull the detergent suction hose out
and immerse it into the detergent
bottle or container.
Screw the lid onto the bottle or the
container.
Install the low pressure nozzle.
Set the deter-
gent dosing
valve to the de-
sired detergent
and concentra-
tion.
Recommended cleaning method
Spray the detergent sparingly on
the dry surface and allow it to react,
but not to dry.
Spray off loosened dirt with the
high-pressure ray.
After operations, dip the filter in
clear water. Turn the dosing valve
to the highest detergent concentra-
tion. Start the appliance and rinse
for one minute.
Interrupting operation
Close the hand spray gun.
The appliance switches off.
Secure the trigger gun. To do so,
push the safety catch towards the
front.
After the interruption:
Release the trigger gun. To do so,
push the safety catch towards the
back.
– 8
EN