Dip Switches - American Hometec AHQ-TC10 Manual De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Select the power capacity setting by setting the dip switches 1 to 3 as shown
3.
in thefollowing figure to the setting you have determined for your application.
Remove 4 screws to remove the cover of the control board. The dip switches
are located on the left bottom part of the control board as shown in the
picture below.

Dip Switches

Dip Switch
Open the front panel of the unit by removing two small screws from the
4.
bottom of the cover and then lift the front cover out. This is a knob to set
the highest temperature. Factory Default Temperature is 104
Figure 5: Highest temperatureSetting
Figure 4: Dip Switch Setting (
MODEL NO
(at 240 v)
AHQ-TC10
ACQ-TC10Y
ACQ-TB03X
Max Temperature Setting)
Temperature MAX(℉/℃)
Setting
AHQ-TC10/ACQ-TC10Y/ACQ-B03X
Min
1
2
3
4
5
6
7
8
9
10
Max
9
SETTING
POWER
1
2
9.5KW
ON
OFF
7.8KW
OFF
ON
4.2KW
OFF
OFF
9.5KW
ON
OFF
8.3KW
OFF
ON
5.5KW
OFF
OFF
3.4KW
ON
OFF
2.4KW
OFF
ON
o
F (40
℃).
70/21
75/24
81/27
86/30
91/33
97/36
102/39
106/41
109/43
115/46
120/49
125/52
3
OFF
OFF
ON
OFF
OFF
ON
/
/
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Acq-tc10yAcq-tb03x

Tabla de contenido