4 groups are controlled: the set drying period count starts as soon
as the end of dispensing has been detected (dispensing EV
closure). If the end of dispensing in another group is detected during
this count, the drying timer is reset. The drying time is set via a
trimmer on the card.
-
No. of turns: 2.5
-
Range: 0 sec. - 10 sec.
Start
dispensing
Drying EV ON
Dispensing EV OF
Dispensing Time
Drying EV ON
LD2 - LD4 - LD5 - LD7
Green leds - ON - coffee EV ON
LD3 = Red
= ON = EV Drying ON
EDS Function (Classic and Basic)
Drying EV OFF
Drying time
The card contains a potentiometer and two switches for setting the
drying time.
F1
=
0.25 fuse A1 cards
F2
=
5A1 outputs fuse
R5
=
Drying time trimmer