3 Installation & Commissioning
Only competent personnel trained, qualified, and approved by Parker domnick hunter should perform installation,
commissioning and service procedures.
Warning
3.1 Recommended system layout
The dryer should be installed with the correct pre-filtration and condensate management equipment to meet both the specification and local
environmental requirements.
Referring to diagram A4 in Annex A, the following equipment is recommended to meet these requirements:
Ref
Description
1
Compressor
2
Wet air receiver
3
Bypass line
4
Isolation valves
The use of a bypass line will allow wet untreated air into the system. It should therefore only be used in extreme
circumstances.
3.2 Locating the equipment
Identify a suitable location for the equipment taking into consideration the minimum space requirements for maintenance and lifting equipment.
When considering the final location of the equipment take into account the noise generated when in use.
The dryer can be installed free standing, secured to the floor via the fastener points provided in the base or secured to a wall using the optional
brackets.
Installation Kits
Part No.
DASMB1
DASMB2
3.3 Mechanical Installation
Once the dryer has been located into position install the piping and filtration for connection to the inlet and outlet manifold. AO grade filtration
can be used at the dryer inlet as shown in diagram A4 of Annex A.
Ensure that each filter condensate drain is suitably piped away and any effluent is disposed of in accordance with local regulations.
Two inlet and two outlet connections are available at the top of the dryer to enable connection from either left or right. Unused connections must
be sealed with the threaded plugs provided.
It is important to ensure that all piping materials are suitable for the application, clean and debris free. The diameter of the pipes must be
sufficient to allow unrestricted inlet air supply to the equipment and outlet gas / air supply to the application.
When routing the pipes ensure that they are adequately supported to prevent damage and leaks in the system.
All components used within the system must be rated to at least the maximum operating pressure of the equipment. It is recommended that the
system be protected with suitably rated pressure relief valves.
A by-pass line may be installed into the system to provide a constant air supply during maintenance.
Ref
5
6
7
Description
608204061
608204062
Description
AO filter
AA filter
Dryer