FAS FASTER GCD Manual Del Usuario página 80

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

28
machine will exclusively use the price information coming from the payment system: in other words it is
not necessary to compile price tables (Commands 03 and 04) butit is sufficient to set command 05
only (see the associated paragraph).
BDV 001 (see the paragraph on the use of the BDV coin mechanism)
MDB (see MDB payment system paragraph).
Command 70 Buzzer operation option:
By setting this command at zero the buzzer is disconnected during machine operation.
Command 73 Enabling the photoelectric cells:
This command should be set at 1 only if the photoelectric cell system is installed. Its function is to
enable=1/disable=0 this device. Note: This setting is valid for both machines (MASTER and SLAVE).
Set the command at 1 (photocells enabled), you automatically enter the menu that allows the inhibition of this
function for the desired selections(delivery without photocell control). To disable the option corresponding to
one or more selections, simply key in the selection number and then set the value at zero.
E
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
N
the same parameters for the SLAVE machine can be set.
G
L
Command 74 Photocell test:
I
This command is for checking that the photocells are working properly. When the type of test to run has
S
been selected, a test procedure is started automatically; the result is displayed on completion.. If there is a
H
problem with the functioning, a second value appears on the display which refers to the problem. See the
table for Command 99 for this second value.
Command 75 Setting the operating parameters of the photocell barrier :
This command allows the operator to view and change the operating parameter of the photocell barrier. This
value is the same for the MASTER machine and any connected SLAVE machines.
Message
"Hyster.HL"
Command 76 System's operating options ("FTC Options "):
Setting this command determines how the machine will react if the product is not delivered. The value can be
set at between 0 and 2. Default = 0.
The meaning of the setting is as follows:
0 = Possibility of another selection; in this case command 63 (single-multisale) must be set at 1 (if it is an
executive payment system the multisale must also be set in the payment system).
1 = Automatic credit delivery; in this case command 63 must be set at 0 (if it is an executive payment system
the single sale must also be set in the payment system).
2 = Further quarter turn: if the product is not delivered the spiral completes a further 1/4 turn and if the
product has still not been delivered then the machine reverts to one of the preceding two options depending
on the single or multisale parameter that has been set.
For this purpose once the value 2 has been set in command 76, the option is disabled for all the
selections by default. Then you automatically access the menu that allows you to enable the option for
the individual spirals. To enable the option corresponding to a spiral simply enter the selection number
and set the value at 1. Vice versa if this value is set at 0 the option is disabled. The option is not
applicable to ½ turn spirals. If the payment system uses Executive protocol, the single-multivend must
also be set on the payment system.
Alternatively, the function can be enabled / disabled for each drawer: selection 91 implies that all the
selections in the first drawer from the top are, for example, enabled for the quarter turn function. Selection
92 = 2nd drawer; 93 = 3rd drawer; 94 = 4th drawer; 95 = 5th drawer; 96 = 6th drawer; 97 = 7th drawer; if
you program the function for selection 99, all the selections in the vending machine will be enabled or
disabled.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: [email protected]
Default value
Meaning
6
This parameter acts on the sensitivity of the reading of the system.
The lower the value set in this parameter , the greater the sensitivity
of the system. The value can vary from a minimum of 5 to a
maximum of 30.
FASTER GCD – Issue 03
Tabla de contenido
loading

Tabla de contenido