Electrical connections
Power supply 230V (a.c.) 50/60 Hz
L-N
24V d.c. gearmotor ( M1) featuring delayed
M1-N1-RALL1
action on opening
24V d.c. gearmotor ( M2) featuring delayed
M2-N2-RALL2
action on closing
Terminals for powering the following accessories:
10-11
- 24V a.c. (normally alternated power)
- 24V a.c. (continuous power) when the emergency
batteries are in operation.
Overall power allowed: 34W
Signal Flasher (socket rating: 24V - 25W max.)
10-E
Open gate indicator-light (socket rating: 24V - 3W max.).
10-5
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Pulsante Stop button (N.C. socket)
1-2
Key selector and/or partial opening button
2-3P
(N.O. socket)
Key selector and/or commands button
2-7
(N.O. contact)
"partial stop" (N.C.) socket
2-C3
"Open during closing" (N.C.) socket
2-C1
Connection of antenna
Possible output of the radio receiver's second
B1-B2
channel (N.O. socket). Socket rating: 5A-24V (d.c.).