Testing An Diode Isotop Module; Check For Shorted Diode; Check For Good Diode - Cebora 337 Manual De Servicio

Ocultar thumbs Ver también para 337:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CEBORA S.p.A.

9 TESTING AN DIODE ISOTOP MODULE

9.1 Check for shorted diode

Using a digital multimeter set in diode mode measurement:
1. Measure between K2 (- black meter lead) and A2 (+ red meter lead);
2. Measure between K1 (- black meter lead) and A1(+ red meter lead);
If you measure a short ( 0 V) in step 1. or 2 or both, the diode module is not usable.

9.2 Check for good diode

1. Measure between K2 (- black meter lead) and A2 (+ red meter lead);
2. Measure between K1 (- black meter lead) and A1(+ red meter lead);
3. Measure between K2 (+ red meter lead) and A2 (- black meter lead);
4. Measure between K1 (+ red meter lead) and A1(- black meter lead);
If you measure a value about 0.3 V in step both steps 1, 2 and measure open circuit
(OL) in steps 3, 4 the diode module is good.
3302336/B
diode isotop schematic diagram
diode isotop module (top view)
39
03/01/2018