Electrical hook up of the hood

35
Electrical hook up of the hood
WARNING: The electronic board for the controls needs to be installed
beneath the work top, close to the body of the hood and at a minimum
distance of 65 cm from all substances or ducting for flammable
substances (gas pipes or ducting for specific liquids).
USEFUL ADVICE: We recommend fitting the electronic board at a height
of at least 10 cm from the ground and at a suitable distance from all heat
sources (e.g., the side of an oven or cook top).
Important :Installation must be carried out in conformity with best
practices, the provisions of the NF.C. 15100 standard and requirements
of electric power providers.
This appliance is delivered with a H 05 VVF power cord that has three
0.75 2mm conductors (neutral, phase and ground). It must be connected
to 230 V single phase current. Use a grounded NF.C.15100 standard
electrical outlet that conforms to the requirements of electric power
providers. This electrical outlet must be accessible.
Make sure the earth electrode conforms to current standards. We cannot
be held responsible for any incident or accident caused by a non-
conforming electrical connection or a non-existent or defective ground.
The fuse for the installation must be 10 or 16 A. If the power cord is
damaged, it must be replaced by a certified power cord. This repair
must be performed by authorised personnel through your retailer or
the manufacturer.
Attention:
If the hood presents some form of anomaly, unplug the appliance or remove
the fuse corresponding to the appliance's power line.
If the appliance is connected directly to the mains, connect the power cord
to a 2-pole wall breaker whose contact opening is at least 3 mm. A fixed
installation is preferred.