2.6.3
POWER SUPPLY CABLE
The unit is supplied fitted for one of the following voltages:
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type
H07RN-F. The cable should be inserted through the cable clamp and firmly fastened. Furthermore, the supply voltage with
the unit functioning should not go outside the value of the nominal tension ±10%.
To have access to the terminal board in order to connect the unit to a supply network having different characteristics from
those provided for, or to replace the supply cable, you need to:
- remove the front panel
- connect the cable to the terminal board according to need, and following the instructions shown on the provided sticker near
the terminal board and on the present booklet.
2.6.4
ADVICE TO THE INSTALLER
Activate the unit according to the use instructions, and explain its operation to the user by consulting the instruction booklet,
illustrating also any manufacturing and/or functional modifications.
Leave the instruction booklet with the user, advising that he/she should refer to it for any future consultation.
2.6.5
CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES
3N AC 380...415 V 50/60 Hz.
2N AC 380...415 V 50/60 Hz.
3 AC 220...240 V 50/60 Hz.
1N AC 220...240 V 50/60 Hz.
3N AC 380...415V; 3 AC 220...240V; 1N AC 220...240V 50/60 Hz.
PE (Earth)
N (NP)
L
3
L
2
L
1
PE (Earth)
N (NP)
L
2
L
1
PE (Earth)
L
3
L
2
L
1
PE (Earth)
N (NP)
L
1
- 13 -
yellow-green
blue
(T)
black
(S)
black
(R)
brown
yellow-green
blue
(S)
black
(R)
brown
yellow-green
(T)
blue
(S)
black
(R)
brown
yellow-green
blue
(R)
brown
Tab. 2