1.
1.1
ELECTRIC FOLDING BRATPAN SERIES OPTIMA
MOD.
E77/BRI7
800 x 700 x 850
E77/BRC7
800 x 700 x 850
SUPPLY VOLTAGE : 3N AC 415V; 3 AC 240V ; 1N AC 240V 50/60Hz.
N.B. : Power absorbed with 3N AC 380V; 3 AC 220V; 1N AC 220V 50/60Hz is approx. 16% lower.
(1) Height max = 985 mm
1.2
TECHNICAL CHARACTERISTICS
STRUCTURE frame made of stainless steel AISI 304, panels and base of stainless steel, mounted on height-adjustable feet.
TANK made of stainless steel AISI 304 (E77/BRI7) and compound (E77/BRC7).
ELECTRIC THERMOSTAT AND SWITCH to control heating elements in 8 positions for optimum power adjustment.
ELECTRICAL HEATING ELEMENTS made of Incoloy.
SAFETY THERMOSTAT to prevent breakages in case if water stoppage.
CONTROL KNOB made of thermally insulated material.
2.
Installation must be performed by qualified technicians according to the law in force.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat-resistant to temperatures of 100°C and must be fireproof.
Before proceeding with the installation, remove the protective plastic film from the relevant parts, eliminating any adhesive
residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be achieved by rotating the adjustable feet.
If the unit is installed by itself, it is advisable to fasten it to make its stability safer.
2.1
INFORMATION ABOUT ELECTRIC FOLDING BRATPAN SERIES OPTIMA
The serial plate is located at back and inside.
DIMENSIONS IN mm.
external
(1)
W x D x H
W x D x H
700 x 480 x 200
700 x 480 x 200
V
tank
Surface
(1)
2
lt.
dm
50
33,6
50
33,6
INSTALLATION INSTRUCTIONS
KW
- 11 -
TECHNICAL DATA
POWER
NET
INPUT
WEIGHT
TOTAL*
kW
kg
9
72
9
72
Mod.
Matr. N°
HZ