Electrical Requirements; Prepare Installation Space; Cutting Out Countertop - Gaggenau VI 424 610 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electrical requirements

You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junction box must be located within 3 feet of the
cooktop connection. It should be easily accessible for
service purposes.
Power Supply
Models VI 414 610, VI 424 610
20 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
All with 39" (1 m) flexible conduit (included)
6

Prepare Installation Space

The kitchen unit must be heat-resistant to at least
200° F (90°C). The stability of the unit must be
maintained after producing the cut-out.
Produce the cut-out in the countertop for one or more
Vario appliances as shown in the installation sketch.
The angle between the cut surface and the countertop
must be 90°.
The cut edges at the sides must be flat to ensure a
good fit of the retaining springs on the appliance. In
laminated worktops, it may be necessary to fit strips at
the sides of the cut-out.
Remove shavings after cutting. Seal cut surfaces for
resistance to heat and so they are watertight.
Pay attention to a minimum gap of 3/8" (10 mm) from
the underside of the appliance to kitchen units.
The worktop must be reinforced if it is less than
20 mm (¾") thick when installed overlapping or less
than 30 mm (1
3
/
") when installed flush. Otherwise, it
16
is not stable enough. Reinforcement material used
must be resistant to heat and moisture.
Notes
The worktop where the appliance is installed
should be able to support a weight of
approximately 60 kg.
The appliance levelling should only be checked
after it is installed in the gap for the built-in unit.

Cutting out countertop

Tabla de contenido
loading

Tabla de contenido