WARNINGS/CAUTIONS
Read all of these SAFETY INSTRUCTIONS and those in the manual
BEFORE installing or using this equipment. Keep this manual handy
for reference/training.
SAFETY
You will find various types of safety information on the following pages
and on the labels attached to Graymills equipment. The following Safety
Statements explain their meaning:
The Safety Alert Symbol means ATTENTION! BECOME ALERT!
YOUR SAFETY IS INVOLVED!
DANGER
The DANGER Symbol means that failure to follow this
safety statement will result in serious personal injury or death.
WARNING
The WARNING Symbol means that failure to follow this
safety statement might result in serious personal injury or death.
CAUTION
The CAUTION Symbol means that failure to follow this
safety statement might result in personal injury or property damage.
NOTE
The NOTE Symbol means failure to follow these instructions
could cause damage to the equipment or cause it to operate
improperly.
Never work with equipment you feel may be unsafe. Contact your
Supervisor immediately if you feel a piece of equipment is in an
unsafe condition.
• Do NOT install near open flames or heat. Do NOT smoke near parts
cleaners.
• Be sure to follow label instructions provided with any fluid used
in this unit. Use only fluids with a flash point of 104°F or higher.
Graymills recommends Super or Regular Agitene® (Flashpoint
approx. 105°F). Do NOT use gasoline, alcohol, carburetor cleaners,
metal strippers or chlorinated solvents. Use of such unauthorized
materials can cause a health and safety hazard which might result
in serious personal injury or death. If you have any questions
regarding the correct fluids to use in this unit, call Graymills at (773)
248-6825 and ask for Customer Service.
• Do NOT contaminate cleaning compounds with any flammable
materials (not less than 104°F flash point), such as gasoline,
alcohol, etc. Drain parts to be cleaned of any flammable material
before placing inside cleaning tank. Even small quantities can
create a dangerous fire hazard.
• If any cleaning solutions are splashed on clothing, remove wet
clothing promptly and thoroughly wash body areas that have been
in contact with the solution. Do NOT permit saturated clothing to
remain in contact with skin.
• Cleaning solutions may irritate skin and eyes. If splashed in eyes,
flush thoroughly with water. Consult Material Safety Data Sheet
(MSDS) and a physician. Always wear appropriate safety items
such as gloves, apron, safety glasses or goggles.
• Follow all directions, Warnings and Cautions for the cleaning
material being used.
• Before performing any maintenance on this unit be sure to
disconnect electric power.
• Unit must be properly grounded to prevent electric shock hazard.
Connect only to three prong outlet. Should cord become cracked,
frayed or damaged in any way, it should be repaired immediately by
a qualified electrician. Never use an extension cord.
• Since operator safety at all times is a priority, we strongly
recommend that, whether or not required by local code, this
equipment be connected only into a power supply equipped with
a "Ground Fault Interrupter" (GFI). All electrical connections
should conform to national/local codes and be made by qualified
personnel.
2
CAUTION
WARNING
CAUTION
WARNING
• Unit is equipped with a fusible safety link cover mechanism
designed to support the open cover at a slightly forward angle. In
the event of a fire, the fusible link will melt at 165°F permitting the
cover to slam shut, cutting off oxygen supply to the fire.
• Never leave the unit unattended with parts in the tank which would
prevent the cover from closing completely in the event of a fire.
Always make sure that the cover remains in its correct, slightly
tilted forward position when open. Do NOT tamper with or remove
the fusible safety link. If the safety link breaks or is lost, do NOT
use the unit. Replace the safety link immediately. Keep the cover
closed when the unit is not being used.
• After extended use, the gas spring could begin to lose some of
its holding ability. If you begin to notice the cover not holding
in the open position, replace gas spring immediately to prevent
inadvertent dropping of cover and potential injury.
• Do NOT load with parts over recommended maximum weight.
Inspect pump and all electrical cords and plugs each time unit is
cleaned. Do NOT use if any wear or damage is noticed until impaired
components are repaired or replaced.
Fill tank to recommended operating capacity range before plugging in
power cord. (See INSTALLATION AND OPERATION Section.)
intrODUCtiOn
The Clean-O-Matic parts cleaner is a heavy duty, multi-functional cleaning
machine for production, maintenance and automotive service. The unique
features of the Clean-O-Matic are designed to save time and money when
cleaning a wide variety of parts and assemblies.
A number of optional accessories are available to enhance the cleaning
ability of Clean-O-Matic parts cleaners. See page 10 for details.
sPeCiFiCatiOns
Make sure that you connect your Clean-O-Matic to a grounded
compatible electrical source. Failure to do so can result in damage to your
unit and/or hazardous condition. Never use extension cords.
Electrical Characteristics
Depending on the model, Clean-O-Matics are available in either 115V
or 230V. To determine the electrical requirements of your model, check
the nameplate located on the side of the tank near the motor. An "A"
designation after the model number indicates it operates at 115V, 60 Hz, 1
ph. A "B" following the model number means the unit is rated at 230V, 60
Hz, 1 ph.
Example: 500-A means a Model 500 Clean-O-Matic with a 115V, 60 Hz,
1 ph motor.
Air Motor (GAM) Characteristics
There is no pilot light or switch. The air connection is on the side of the
tank with the valve.
Liquid Capacities
The liquid capacity of your Clean-O-Matic is as indicated below:
Model
Maximum
300, 500
42 gals
800
85 gals
900, 902
117 gals
Weight Limitations
The maximum weights which can be placed on the tank bottom and work
shelves of your Clean-O-Matic are indicated below:
Model
Bottom
300, 500, 800
500 lbs.
900, 902
750 lbs.
Recommended Cleaning Fluids
The Clean-O-Matic is designed to be used with combustible (flash
point over 104°F) petroleum based cleaning fluids such as Graymills
CAUTION
CAUTION
CAUTION
WARNING
Minimum
20 gals
50 gals
50 gals
Shelves
150 lbs.
200 lbs.