Certified Quality; Installation Steps - Spartherm Mini Manual De Instrucciones

Tabla de contenido

1.1. CERTIFIED QUALITY

OUR FIREPLACE INSERTS HAVE BEEN TYPE-TESTED AND LABELLED
AS PER DIN EN 13229
A = Fireplace door, manual closure
• Open operation may be possible
• Multiple use of chimney prohibited
We also recommend operating Type A devices with closed view-
ing panes. This improves the utilization of the wood energy and
increased operational safety. When the fireplace door is open, air
movement or weak/irregular chimney draft may quickly cause soot
or odors to permeate the room.
Valid for the following devices: multiple use of the chimney and
open operation is prohibited for Type A with manually closing
fireplace door!
Speedy MR/MRh/M/Mh
Varia Sh
Varia C-45h
A1 = Fireplace door, automatic closure
• Closed operation
• Multiple use of chimney possible
For Type A1, the fireplace door must always be locked in order to
prevent combustion gas leakage (except when loading/unloading).
These fireplace inserts have automatically closing fireplace doors
so that the doors are only opened when the fireplace has to be
serviced (removing ashes, re-supplying with fuel, etc.). For this
fireplace insert, multiple use of the chimney, etc., is possible.
Modifying the closing mechanism of Type A1 is prohibited for
safety reasons, and would render the guarantee and operating
permit invalid. The guarantee and operating permit would also be
rendered invalid if the customer modified the technology of any
other area of the fireplace insert. You should discuss the required
type with your customer or with the local building code inspector
before ordering it.

1.2. INSTALLATION STEPS

1.
The feet are included with the device for transport purposes.
2.
Before unscrewing the locking screw for the counterweights
(transport security for liftable fireplace inserts), carefully
place the device on its „back" so you can attach the feet.
3.
As required, use the clamp included to attach the safety
valve lugs to the adapter in the required position at this time.
4.
The fireplace has to stand perfectly plumb-vertical and
horizontal.
5.
A horizontal connection to the chimney is possible by rotating
the flue gas dome. To do this, open the clamp, put the flue
gas dome in position and clamp it in place again.