2
Screw T30 (3x)
3
Fan cables
4
Heat sink
4. Remove dust and specks of dirt by blowing on the heat sink, for example by using a
small air compressor or a can of compressed air. The heat sink may also be rinsed with
pure water.
5. Put the heat sink cover back in its original position and tighten the screws (torque
2.4 ±0.2 Nm).
6. Put the sunshield back in its original position and tighten the screws (torque 1.2 ±0.1 Nm).
7. Connect the multi-connector cable to the connector on the camera.
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available on the CD supplied with the
product and from the support pages on www.axis.com/techsup
To reset the product to the factory default settings:
1. Press and hold the control button and the power button for about 15–30 seconds until
the status LED indicator flashes amber. See Hardware Overview, on page 10.
2. Release the control button but continue to hold down the power button until the status
LED indicator turns green.
3. Release the power button and assemble the product.
4. The process is now complete. The product has been reset to the factory default settings.
If no DHCP server is available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the
password and access the video stream.
It is also possible to reset parameters to factory default via the web interface. Go to Setup
> System Options > Maintenance.
Further Information
The User Manual is available at www.axis.com
Visit www.axis.com/techsup to check if there is updated firmware available for your network
product. To see the currently installed firmware version, go to Setup > About.