Power Module Features

There are two separate UPS system modules: a power module and a battery module. Familiarize yourself with the location and function
of the features on each module before installing and operating the UPS system. The power module is described below. The battery
module is described in a separate manual.

Control Panel

1
LCD Display: This backlit display indicates a wide range of UPS operating conditions and diagnostic data. It will illuminate after the
UPS has been properly installed and started up.
2
MAINTENANCE BYPASS LED: This red LED will illuminate when the UPS is providing filtered mains power without engaging its
converter or inverter. Connected equipment will not receive battery power in the event of a blackout when this light is illuminated.
RESERVE POWER LED: This green LED will illuminate to indicate the presence of a reserve power breaker and reserve power source
3
connected to the UPS.
4
RECTIFIER LED: This green LED will illuminate to indicate the UPS rectifier is operating.
BATTERY LED: This orange LED will illuminate when the UPS is discharging the battery to provide connected equipment with AC power.
5
INVERTER LED: This green LED will illuminate constantly to indicate the UPS inverter is activated.
6
RESERVE POWER STATIC SWITCH LED: This green LED will illuminate when the UPS is powering connected equipment through a
7
reserve power source connected to the UPS.
8
INVERTER MC LED: This green LED will illuminate to indicate connected equipment is supplied with power through the UPS inverter.
9
AC OUTPUT LED: This green LED will illuminate constantly to indicate your UPS is supplying AC power to connected equipment.
EMERGENCY POWER OFF Button: In case of emergency, press this button to turn off the UPS rectifier, inverter and output. After
10
pressing the button, it will remain down until reset. To reset the UPS system and restore output, press the EMERGENCY POWER OFF
button until it pops back up.
11
ON Button: This button, when used with the  button, turns the UPS inverter on. To turn the UPS inverter on, simultaneously press the
ON and  buttons and hold for 3 seconds before releasing.
12
OFF Button: This button, when used with the  button, turns the UPS inverter off. To turn the inverter off, simultaneously press the OFF
and  buttons and hold for 3 seconds before releasing.
13
 ,  and  Buttons: These buttons control the LCD Display and setting parameters.
2
3
4
5
7
8
9
6
10
11
12
CoNTroL PANEL
3
1
13