PROBLEMS & SOLUTIONS
PROBLEM
Pump does not work.
Electric System does
not work.
A bad sparying.
Pump does not
take pressure.
Manometre needle
ocillates a lot.
CAUSE
Pressure switch blocked
Pressure swith is working.
Pump is failing.
Pump is failing.
Failed fuse.
Failing connections.
Battery does not give energy.
Damaged ON/OFF Switch
Not enough flew, because
aspiration fliter is durty.
Nozzle filter is durty.
Partial blockage in some
connection & impeding correct
flew to arrive.
Pump fails.
Spoiled nozzle.
Discharged battery.
Acumulated air in the circuit.
Dirty filter.
Strangledhold in some
connection.
19
SOLUTION
Adjust firing pressure or replace
the switch
Open a bit the returning.
check fuse and connections
Replace with other.
Change it.
Restore the connection.
Charge the battery or replace it
Change it.
Clean it.
Clean it.
Check hoses & undo bloching.
Look over this specific sunject.
Change it.
Charge it.
Open the returning to máximum
for 15 seconds, and adjuste
pressure after.
Clean it.
Undo stranglehold.