Grounding Instructions - Alliance Laundry Systems D009C Instalación/Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
.
1
115 ± 12
V.A.C.
5
4
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
1
L1
2
Ground
3
Neutral
4
Round Grounding Prong
5
Neutral Side
Figure 19
30
2
3
0
V.A.C.
115 ± 12
V.A.C.
D799I
D799I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Grounding Instructions

The dryer unit must be grounded. In the event of
G
malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a
path of least resistance for electric current. The
dryer unit is equipped with a cord having an
equipment-grounding conductor and a three-
prong grounding plug. The plug must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer unit is
properly grounded.
DO NOT modify the plug provided with the
G
dryer unit – if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
If the laundry room's electrical supply does not
G
meet the above specifications and/or if you are
not sure the laundry room has an effective
ground, have a qualified electrician or your local
electrical utility company check it and correct
any problems.
W153
510975

Capítulos

Tabla de contenido
loading

Tabla de contenido