Alliance Laundry Systems D009C Instalación/Operación página 25

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE: The power cord (pigtail) is NOT supplied with
the electric dryer. Type of pigtail and gauge of wire
must conform to local codes and instructions.
The method of wiring the dryer is optional and subject
to local code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIRE only.
Shorter than 15k (4.5 m) – use 10 A.W.G.
Longer than 15k (4.5 m) – use 8 A.W.G.
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
2
30 Ampere Fuses or Circuit Breaker
3
Neutral Wire
510975
A typical
INTERMEDIATE
30-Amp
FUSE BOX (may
Three-Wire
be omitted if
Receptacle
service entrance
NEMA Type
box is fused)
10-30R
WALL
RECEPTACLE
120 ± 12
V.A.C.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
POWER SUPPLY
5
L1
L2
PIGTAIL CONNECTION
4
Metallic or Non-Metallic Sheathed Cable
(Copper Wire Only)
5
Pigtail to Dryer (Refer to NOTE above)
6
Neutral
7
Terminal Block in Dryer
Figure 13
POWER SUPPLY
1
2
3
INTERMEDIATE
SHUT-OFF BOX
(may or may not
4
6
7
L1
L2
DIRECT CONNECTION
Installation
be fused)
D816I
23

Capítulos

Tabla de contenido
loading

Tabla de contenido