SPECIFIC WARNINGS
The electrical safety of this unit is assured only when it is correctly connected to an efficient earthing system as stated in
the electrical safety regulations in force; the Manufacturer declines any responsibility for the non-compliance with these
safety regulations.
It is necessary to verify this fundamental safety requisite and, in case of doubt, ask for an accurate testing of the system by
professionally qualified personnel.
The Manufacturer cannot be deemed responsible for any damages caused by the lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green).
2.5.2
EQUIPOTENTIAL
The unit should be included within an equipotential system whose efficiency must be tested according to the law in force.
The connecing screw is placed in the back position.
2.5.3
POWER SUPPLY CABLE
The unit is supplied fitted for the following voltages:
2.5.4
CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES
3N AC 380...415 V 50/60 Hz
3 AC 220...240 V 50/60 Hz
1N AC 220...240 V 50/60 Hz
MODELLO
TIPO DI TENSIONE
AC 220...240 V 50/60 Hz
3 AC 220...240 V 50/60 Hz
3N AC 4000...415 V 50/60 Hz
F14+14E/M
F14E/M
Mass.
N° cavi
Mass.
A/fase
mm
2
A/fase
12
12+12
3 x 4
12
12+12
4 x 2,5
12
12+12
5 x 2,5
PE (Earth) yellow - green
N (NP) blue
L
L
L
PE (Earth) yellow - green
L
L
L
PE (Earth) yellow - green
N (NP) blue
L
1
- 13 -
N° cavi
mm
2
3 x 4
4 x 2,5
5 x 2,5
(T)