Time switch
Rex2000 w72/1
24
6
5 6
7
3 4
1 2
18
12
OK
ME NU
2 4
6
7
5 6
3 4
1 2
1 8
1 2
OK
U
M EN
498 32
044 09
Presentation
Summer/winter
Real time, switching time
Clr = delete switching times
Copy = copy switching times
Actual day of the week
or program day
Segment display of the
existing program
1 segment = 30 minutes
Button Menu
activates the menu or
breaks off the process
Button moves the flash
Technical data
Supply voltage:
230V 50/60Hz
Consumption:
ca. 0,8 W
changeover contact 16A 250V~µ cos ϕ = 1
Contact rating:
Parallel compensation:
60VA max. 7µF
Accuracy:
±1 s/day under typical installation conditions
Terminal capacity:
single strand
1,5 to 4 mm
Program pictures:
56
Battery reserve:
10 years
Storage ambient:
-20°C to +60°C
Working ambient:
-20°C to +55°C
Safety notice
This product may be installed only by a qualified electrician. Non-compliance may result in a
fire hazard or electric shocks. Before installation, read the operating instructions and observe
the product-specific requirements for the installation location. Use only original spare parts for
repair and maintenance. All Legrand products may be opened and repaired only by specially
trained Legrand personnel. Unauthorised opening and repair by other persons will invalidate
all claims for liability, replacement or warranty services. To ensure electromagnetic tolerance
as required by the provisions to identify CE- products in applicable ambits of EMV 89/336/
CE-lines, adequate protective measures have to be found for consumers of high voltage dro-
pout - current ( for example motor run devices or lamps exceeding power rating of 800W ) or
commutation – times < 24 seconds. The device contains a LiMgO2 primary cell. When the
product reaches the end of its life, this cell must be correctly removed and disposed of in
accordance with national legislation and the requirements of environmental protection.
Function
The Rex2000 D21w is a digital 7 day time switch with a circular segmented display. Up to 8 program pictures can be set. A program picture
incorporates both ON and OFF time. If no button is pressed for 60 seconds during programming the time switch goes back to the start positi-
on. The copying function enables program to be copied to other days. Minimum switching time is 1 minute. The switching times are protected
but can be overlaid by other programs. Programs are displayed with a minimum segment size of 30 minutes. The time and the week days are
presented digitally. The summer-/winter changeover can be programmed for hand or automatic operation.
Menu
SET TIME CHECK... ON
Day/month/year
PROG DATE NEW...OFF
SU/Wi
D/M/Y
Symbol for automatic operation
24
Symbol for manual override
18
6
Symbol for continuous override ON
1234567
Symbol for continuous override OFF
12
State of contact
ON
OFF
MENU
OK
Button OK
confirms the input
Button minus and plus
changes the values
Mains failure
Mains failure will be displayed by no
U. Buttons are inoperative.
Reset is possible.
496 05
496 04
496 03
120V 50/60Hz
24V AC/DC
multi strand
2
2
1,5 to 2,5 mm
1. Starting
Reset 1 Switching program remains
Press
Reset 2 Switching program deleted
Press all 5 buttons together.
First release button
all other buttons.
2. Setting actual time
Button
Select SET TIME... with button
with button
SET TIME with button
Set actual hour with buttons
with button
Set actual minute with buttons
with button
Operating instructions
Connection
1
4
L
N
1200W
1200W
2300W
1800W
MENU
together.
MENU
, after 3 seconds release
MENU
activates the menu.
and confirm
OK
. Confirm once more
OK
.
and confirm
OK
.
and confirm
OK
.
GB
®
2
100W
100W
2300W
1800W
24
18
6
1234567
12
SET TIME
24
18
6
1234567
12