The delay time will be started by pressing the START button.
When the remaining delay time has reached 0, the wash process will be started automaticaly.
ECONOMIC ?
If ECONOMIC is requested at the start of a new wash cycle, by pressing:
YES : The water level at the executed wash cycle will be 20% units less then the programmed level.
NO
: The water level at the executed wash cycle will be the same as the programmed level.
ADVANCE
You can advance a program by pressing the START button. The wash/spin sequence in execution
will be skipped and the next sequence will be started.
Press the ARROW RIGHT button to increase the sequence time.
Press the ARROW LEFT button to decrease the sequence time.
CONTINUE ?
A program can be interupted due to:
- pressing to STOP button
- a pause signal that has been programmed
- opening the soap dispenser door
- a power interruption
Press START if you want to restart the interrupted sequence.
Press STOP to finish the interrupted program. The tumble sequence will be executed.
WAIT XXX Sec
When the program has been interrupted, before you can interact with the wash computer, you have
to wait XXX Seconds until the washer/extracter gets into a safe state.
HOW TO HANDLE FAILURE MESSAGES
When some failure has been detected by the Full Control Wash Computer, a failure message will
be generated to inform the operator about problem.
Check the Programming manual and/or the installation manual concerning the occured problem.
4.2.6.HOW TO OPEN THE DOOR BY FAILURE
If the diagnostic Error Messages TOO Hot and/or Water in Cage are displayed, do not open the
door by the mechanical override. If there is still hot water in the drum, you can get burned
severely.You have to wait until the water gets drained or until the water has cold enough until it is
safe enough to open the door. It is up to the operator to take the necessary precausions so that
nobody gets burned.
To Adjust and create new program's
See Programming manual.
Maintenance
See Maintenance manual.
Installation
See Installation manual.