Installation Considerations
Know in advance what type of trim kit
is to be used. Installation requirements
vary.
Additional valve(s) may be
required. Please refer to page 18.
•	Some	 municipalities	 do	 not	 permit	 installations	
that	 allow	 the	 use	 of	 two	 or	 more	 shower	
functions	 simultaneously.	 Please	 know	 and	
follow	all	applicable	local	plumbing	codes.	
•	For	 best	 results,	 Hansgrohe	 recommends	 that	
this	unit	be	installed	by	a	licensed,	professional	
plumber.
•	Please	 read	 over	 these	 instructions	 thoroughly	
before	 beginning	 installation.	 	 Make	 sure	 that	
you	 have	 all	 tools	 and	 supplies	 needed	 to	
complete	the	installation.
•	Do	not	remove	the	plastic	installation	box	from	
the	valve.		
For correct function of the valve, the
hot supply must be plumbed to the hot
inlet (left) and the cold supply must be
plumbed to the cold inlet (right).
•	The	connections	on	the	valve	are	¾	NPT.		½	NPT	
lines	may	be	used	if	suitable	for	the	installation.	
The	installer	must	provide	¾	-	½	adapters.
The outside surface of the finished wall
must fall between the "min" and "max"
markings on the iBox.
Important!
•	The	cartridge	is	included	with	the	trim	kit.		The	
cartridge	will	vary,	according	to	the	type	of	trim	
kit.	
•	The	cartridge	has	an	integrated	high	temperature	
limit	 stop	 which	 may	 be	 reset	 to	 comply	 with	
local	plumbing	codes.		
•	To	 prevent	 scald	 injury,	 the	 maximum	 output	
temperature	 of	 the	 shower	 valve	 must	 be	 no	
higher	 than	 120°F.	 	 In	 Massachusetts	 the	
maximum	 output	 temperature	 of	 the	 shower	
valve	can	be	no	higher	than	112°F.		
•	Protect	 the	 rough	 from	 freeze	 damage.	 	 In	 the	
event	of	freezing	temperatures,	drain	the	pipes.
3