Alliance Laundry Systems HC18SN2 Operación Y Mantenimiento página 12

Ocultar thumbs Ver también para HC18SN2:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operation
Display
FP 1
Program identification code (ROM)
(this is an example only)
HoLd
Wait...power has just been turned on
CY
Cycle (followed by two-digit number)
tESt/CYC*
Test cycle selected
FAr
Degrees Fahrenheit
CEL
Degrees Celsius
HEAt
Auxiliary heat enabled
noHt
Auxiliary heat disabled
tFIL
Temperature-controlled fill enabled
ntFL
Temperature-controlled fill disabled
CooL
Automatic cool-down enabled
noCL
Automatic cool-down disabled
Ag 1
Agitation 1 selected (90% agitation)
Ag 2
Agitation 2 selected (33% agitation)
Ag 3
Agitation 3 selected (10% agitation)
Ag 4
Agitation 4 selected (6.7% agitation)
AgSn
Agitation speed normal
AgSL
Agitation speed low
n
PU
P
Pump output enabled (future use only)
n
nP
P
Pump output disabled (future use only)
PrE
Prewash segment (1st of 11 segments)
UASH
Wash segment (2nd of 11 segments)
FIL1
First fill (3rd of 11 segments)
FIL2
Second fill (4th of 11 segments)
FIL3
Third fill (5th of 11 segments)
FIL4
Fourth fill (6th of 11 segments)
FIL5
Fifth fill (7th of 11 segments)
FIL6
Sixth fill (8th of 11 segments)
FIL7
Seventh fill (9th of 11 segments)
FIL8
Eighth fill (10th of 11 segments)
FIL9
Ninth fill (11th of 11 segments)
CFIL
Cold fill
bFIL
Warm fill (both hot and cold)
HFIL
Hot fill
AFIL
Auxiliary fill (Setup option)
Lo
Low water level
*Display indications separated by a slash (/) represent a flashing display.
10
Display Indications for V-Series – Non-Coin
Meaning
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Display
n
Ed
Medium water level
HI
High water level
SUP1
Supply 1
SUP2
Supply 2
SUP3
Supply 3
SUP4
Supply 4
SUP5
Supply 5 (Setup option)
SUP6
Supply 6 (supply 1 and 5)
SUP7
Supply 7 (supply 3 and 4)
SLo/For
Gentle wash speed, forward direction
SLo/rEv
Gentle wash speed, reverse direction
n
nor
/For
Normal wash speed, forward direction
n
nor
/rEv
Normal wash speed, reverse direction
drAI
Drain enabled
nodr
Drain disabled
dISt
Distribution (load balancing before
extract)
n
SPIn/tI
E*
Reads "SPIn" for one second, then
"tI
SPn1
Lowest of three spins
SPn2
Middle of three spins
SPn3
Highest of three spins
STOP
Stop routine
SdLY
Spin coast delay
donE
Cycle and stop routine have ended
dFLt
Drive fault detected
door
Door not properly closed
bAL/FAIL*
Balancing routine failed during test cycle
after 10 attempts to balance load
FILL/STOP*
Programmed water level not reached
after 30 minutes
FULL
The computer detects low water level or
higher when none should be present
rotA
Computer detects possible rotation of
motor when there should be none
tSFL
Temperature sensor failure or
temperature out of range
Table 3
Meaning
n
E" followed by time for spin
F232137
Tabla de contenido
loading

Tabla de contenido