20 PROBLEMS TO BE RESOLVED BEFORE CALLING THE SERVICE CENTER

If the appliance is not working, the causes of the malfunction can be identified and resolved by referring to sec-
tion 19. If, on the other hand, a general alarm is on, run the following checks before calling the service center.
PROBLEM
The coffee is not hot
The coffee is not creamy
enough
The coffee runs out too
slowly.
The coffee runs out too
quickly.
The coffee does not
come out of one of the
spouts.
When coffee beans are
being used and the
and
buttons are pressed,the
appliance does not deliver
coffee, but only water.
When the
button is
pressed, the appliance
does not turn on.
The infuser cannot be
removed for cleaning.
Ground coffee is being
used (not beans) and the
appliance does not deliv-
er the coffee.
22
CAUSE
• The cups have not been preheated
• The infuser is too cold
• The coffee is ground too coarsely
• Wrong type of coffee is being used
• The coffee is ground too finely.
• The coffee is ground too coarsely.
• The spout holes are blocked.
• The ground coffee may be blocked in
the funnel.
• The appliance is not plugged in.
• The appliance is on. The infuser can
only be removed if the appliance is off.
• Too much ground coffee has been
added.
• The
button has not been
pressed and the appliance has used
both the ground coffee added and the
coffee ground by the mill.
• Ground coffee has been added when
the appliance is off.
SOLUTION
• Heat the cups by rinsing them in hot water or leaving them
for at least 20 minutes on the cup warmer tray on the lid
(see section 6, note 3).
• Heat the infuser by pressing the
the coffee (fig. 12, see section 6, note 3).
• Turn the grinding adjustment knob one click toward the
number 1 (see section 8).
• Use a type of coffee for espresso coffee makers.
• Turn the grinding regulator one click toward the number 7
(see section 8).
• Turn the grinding regulator one click toward the number 1
(see section 8).
• Scrape off the dry coffee residues with a needle (fig. 29).
• Remove the ground coffee inside the funnel using a knife
(see section 9, note 5).Then clean the infuser and the inside
of the appliance (see description in section 16.2).
• Check that the power cable is plugged into the outlet.
• Turn the appliance off and remove the infuser (see section
16.2). IMPORTANT: The infuser can only be removed if the
appliance is off. Attempting to remove the infuser with the
appliance on may cause damage.
• Remove the infuser and thoroughly clean the inside of the
appliance, as described in section 16.2. Repeat the operation
using a maximum of 1 measuring scoop of ground coffee.
• Thoroughly clean the inside of the appliance as described in
section 16.2. Repeat the operation, first pressing the
button as described in section 9.
• Remove the infuser and thoroughly clean the inside of the
appliance, as described in section 16.2. Repeat the opera-
tion, but switch the appliance on first.