RIB NORMAL RARK 230V Manual Del Usaurio página 29

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

J1
L-N
Main power supply 230Vac 50/60Hz upon request)
J2
COM
Common contact
LSC
Closing limit switch contact (NC)
LSO
Opening limit switch contact (NC)
LSSC
Not used
LSSO
Not used
TLC
Vehicle presence signal (NO) (only when switched to PARK mode)
PHOT. NC
Photocells contact (NC)
EDGE NC
Safety strip contact (NC)
COM
Common contact
D+ TEST
Safety strip self-test power supply +12Vdc 500mA max
D+
Accessories power supply +12Vdc 500mA max
D-
Accessories power supply -12Vdc 500mA max
J3
OPEN 2
Barrier opening button 2 contact (NO) (only when switched to PARK
mode)
SIGNAL
Barrier open signal 12Vdc
Buzzer - Acoustic signal connection (12Vdc max 200 mA)
AERIAL
Radio antenna
Blinker (max 40W)
J4
U - MOTOR Motor common connection
V-W -
Motor inverters and condenser connection
MOTOR
J5
OK CLOSE
Immediate closure command contact (only when switched to PARK
mode)
OPEN 1
Open1 button contact (NO)
CLOSE
Close button contact (NO)
STOP
Stop button contact (NC)
K BUTT.
Single pulse button (NO)
COM
Common contact (common line for all the commands and safety
inputs)
J6
PROBE
Heating probe connection terminal block (code ACG4666 optional)
J7
RADIO
Built in radio module
J8
AUX. ATT.
Card 1 relay connector (code ACQ9080) for management of courtesy
light or boom arm locking magnet. Card 3 relay connector (code
ACQ9081) for management of courtesy light or boom arm locking
magnet and traffic lights.
J9
SW PARK
DO NOT TOUCH THE JUMPER! IF REMOVED THE OPERATOR DOES
NOT FUNCTION!
RELAY AND MOTOR COMMAND
K1 => Opening direction command
K2 => Closure direction command
Q4 => TRIAC - Opening and Closing motor command
Q5 => Blinker command
POINT B - SETTINGS
DIP 1 (ON)
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2 (ON)
PROGRAMMING (See Point D)
DIP 1-2
STORING/ERASING RADIO CODES FOR MOTOR
CONTROL (See Point E)
DIP 3
ON
- Automatic Closing ENABLED (max 5 min)
OFF - Automatic Closing DISABLED
DIP 4
ON
- AUTOMATIC Radio Receiver Command
OFF - STEP BY STEP Radio Receiver Command
DIP 5
ON
- AUTOMATIC single pulse command (K BUTT.)
OFF - STEP BY STEP single pulse command (K BUTT.)
DIP 6
ON
- Operation in PARK MODE
OFF - Operation in NORMAL MODE
WARNING:
The PARK MODE enables or disables some features and commands:
- If NORMAL MODE is enabled, OPEN2 command, OK CLOSE command and TLC
A - CONTROL PANEL FEATURES
J4
J1
S3
TR2
J9
J5
DIP12 ON to instal the PARK 230V control panel on Normal
barriers.
J10
SW RADIO
DO NOT TOUCH THE JUMPER! IF REMOVED THE OPERATOR DOES
NOT FUNCTION!
S3
PROG.
Programming button
TR2
TRIMMER
Not available
LOW
SPEED
(Traffic Light Control) input, are not enabled.
- If PARK MODE is enabled all commands are enabled.
DIP 7
ON
- boom arm locking magnet ENABLED (ACQ9080 or ACQ9081 optional
cards)
OFF - courtesy light operation ENABLED (ACQ9080 or ACQ9081 optional cards)
If none of the optional card is connected, turn DIP7 to OFF.
DIP 8
ON
- in PARK MODE the OPEN2 button is always enabled
OFF - in PARK MODE the OPEN2 button works if there is no vehicle on the
magnetic sensor connected to the TLC input (TLC contact opened).
DIP 9
ON
- safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 10 ON
- after the blackout the boom arm automatically closes
OFF - after the blackout the boom arm remains still on the point it was when
blackout occurred
DIP 11 OFF for NORMAL barrier
DIP 12 ON
for NORMAL barrier
DIP 13 ON
- Blinker operation with intermittent power supply
OFF - Blinker operation with fixed power supply
DIP 14 ON
for NORMAL barrier
DIP 15 ON
for NORMAL barrier
DIP 16 OFF for NORMAL barrier
LED WARNING
29
J10
J2
J3
G
B
J8
J7
J6
Tabla de contenido
loading

Este manual también es adecuado para:

Aa50000Normal park 230v

Tabla de contenido