Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Separator will not
operate
Overload protection
disabled due to over-
heating

Technical data:

Max air volume
Material amount (at 100 g/m
Max negative pressure
Max. material length **
Max. height X
Motor / gear
Weight
*: Material amount is indicative. For specific capacity, contact Kongskilde
**: Guiding maximum material length that could be separated
Safety switch disconnected
Overload protection disabled due
to overheating
Missing signal from device control
unit
Fuses defect
Foreign object in the separator
Rotor is frozen and stuck
Motor or gear defect
Rotor deformed
Overload protection incorrect
adjusted
Major decrease in voltage supply
Fuses defect
or 100 µm) *
2
Turn on safety switch
Refer to "Overload protection disabled due to over-
heating"
Check control unit
Locate cause of fuse malfunction and replace fuses
Remove foreign object
Defreeze with hot water or air
Replace gear motor
Replace rotor
Adjust correctly
Replace supply cables to larger cross section
Locate cause of fuse malfunction and replace fuses
RVS 5000
RVS 10000
5.000 m
/h
10.000 m
3
1.200 kg/h*
2.000 kg/h*
-35 kPa
260 mm
1.225 mm
1.600 mm
1,5 kW / 17 rpm
2,2 kW / 17rpm
340 kg
RVS 20000
/h
20.000 m
3
4.000 kg/h*
-20 kPa
-15 kPa
350 mm
520 mm
2.300 mm
4,0kW / 17 rpm
600 kg
1240 kg
/h
3
15
Tabla de contenido
loading

Este manual también es adecuado para:

Rvs 5000 s3 or 50 hz iecRvs 5000 s3 cr 60 hz cusRvs 5000 s3 or 60 hz cusRvs 5000 s6 cr 50 hz iecRvs 5000 s6 or 50 hz iecRvs 5000 s6 or 60 hz cus ... Mostrar todo

Tabla de contenido