Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
the valve should be replaced if any signs of over-
load or leakage is detected. The sensor needs to
be replaced after each explosion.
The brush shoe has been designed to last at least
one year of continious operation, and should be
replaced annually. In case any substantial wear is
detected within a shorter period, the brush shoe
should be replaced anyway, and the reason for the
wear examined.
The ground straps connecting all major parts of the
separator, should always be securely installed dur-
ing operation. The grounding points are indicated
by an earth symbol sticker as shown below. Annu-
ally check for damaged or loose connections, and
measure the resistance between the top of both M8
threads. The resistance in each connection must
not exceed 10
Ohm acc. to EN 60079. If the value
6
is exceeded, check for falty connections.
Lubrication of the gear:
The gear is provided with mineral oil, ISO VG 220, for
operation in a region of ÷10 - 40°C. At working temper-
atures outside this area, synthetic oil should be used.
Recommended synthetic oil types are:

Troubleshooting:

Fault
Abnormal noise from
the rubber blades
during operation
Direction of rotation
reversed
Material has difficul-
ties from falling out
of the separator, or
the suctional effect
at productional loca-
tion reduced
14
Cause
Incorrect adjustment of the plastic
edges
Foreign object in the separator
Connection of phases reversed
Worn out rubber blades
Material is piled up in lumps
Material is not removed immedi-
ately on outlet side
Material fall velocity to low
Material is supplied in to large
amount
BP Enersyn SG-XP 220
Castrol Alphasyn GS 220, PG 220, EP 220, Tribol
800/220, 1510/220 or Optigear Synthetic X 220
Fuchs Renolin PG 220 or Unisyn CLP 220
Klüber Klübersynth GH 6-220 or GEM 4-220 N
Mobil Glygoyle 220 or SHC 630
Shell Omala S4 WE 220 or S4 GX 220
Maintain the geared motor according to the manufac-
turer's instructions.
Separator type
Oil quantity litres
RVS 5000
RVS 10000
RVS 20000
Unmounting of the ATEX
versions:
The separator should be thoroughly cleaned internally
by vaccum cleaning or the like, to avoid any dust explo-
sions in connection with the unmounting of the separa-
tor. Observe all local regulations concerning correct
recycling.
Remedy
Adjust the plastic edges according to "Service and
maintenance"
Remove foreign object
Connect L1, L2 and L3 correct
Renew rubber blades (and possibly also plastic
edges)
Composition of material should be modified at pro-
ductional location
Ensure sufficient emptying
Composition of material should be modified at pro-
ductional location
Material amount should be reduced
0,7
1,8
4,5
Tabla de contenido
loading

Este manual también es adecuado para:

Rvs 5000 s3 or 50 hz iecRvs 5000 s3 cr 60 hz cusRvs 5000 s3 or 60 hz cusRvs 5000 s6 cr 50 hz iecRvs 5000 s6 or 50 hz iecRvs 5000 s6 or 60 hz cus ... Mostrar todo