E7: Pump status detection

The pump status detection signals via the system message Er88 if the pump is operating correctly. The
status detection is activated in the default setting.
Proceed as follows
1.
Press
several times until E7 appears in
the display.
2.
Keep
pressed for 5 s until the value 0 or
1 is indicated in the display.
3.
Press
to change the value.
6.6

Reading out the number of cleaning cycles

6.6.1

Cleaning cycles in 24 hours

Proceed as follows
Press
and
Information
• To cancel and exit the menu: Either wait for 10 s or press
• To cancel and exit the menu: Either wait for 5 s or press
Adjustable range: 0 or 1
• 0: The pump status detection is deactivated.
• 1: The pump status detection is activated.
• Cancel without saving and exit the menu: Press
Information
The sum of the automatic and time-dependent cleaning cycles is saved.
for 5 s.
The 4-digit value is displayed in groups of two digits that appear in
succession in the display.
Example:
01-17: Represents 117 cleaning cycles
The number is repeated five times after an extended pause to make it
easier to read:
01-17---01-17---01-17---01-17---01-17
Note:
If the mains voltage is switched off, the counter is reset to 0.
Note:
Due to the self-test of the filter system very different values may be
displayed. The self-test monitors the automatic cleaning process. The test
is carried out continuously in a 2 × 24 hour cycle. The test is only active
from a water temperature >12 °C.
• First 24 hour cycle
• Second 24 hour cycle
− If at least one automatic cleaning process is detected, the cycle is
repeated after the cleaning process has finished.
− If no automatic cleaning process is detected, the second 24 hour cycle
starts once the first has finished.
− The time-dependent cleaning cycle is deactivated. This reduces the
number of cleaning cycles.
− If at least one automatic cleaning process is detected, the first 24 hour
cycle starts again once the cycle has finished.
− If no automatic cleaning process is detected, the system message Er22
is triggered at the end of the cycle. The time-dependent cleaning cycle
starts again. If an automatic cleaning process is then detected, the first
24 hour cycle starts again. The system message Er22 is automatically
reset.