Setting Up the Camera Using an RM-P2580
POSITION FUNCTION SET Screen
This screen sets the configurations of functions relating to pictures taken in preset positions.
Item
POSITION TITLE ...
Sets the titles for the 99 preset positions and the home position. Titles can be up to
16 characters in length and are shown in the display.
P. 37, "POSITION TITLE Setup"
IRIS MODE
Determines the lens iris adjustment mode.
AUTO
AUTO+
AUTO–
MANUAL : for manual iris adjustment.
BLC
Sets of area of back light compensation. Use this function when the object ap-
pears dark (under auto iris control) because of the presence of a bright light source
behind it. This function make it possible to place the unnecessary light source out-
side the photometry area.
MEMO
When the item "ExDR MODE" (
"---" is displayed. Under this condition, the settings to the item "BLC" cannot be varied.
W. BALANCE
Determines the setting of the white balance adjustment. The white balance can be
adjusted for lighting conditions with color temperatures from 2500K to 8000K.
ATW : Auto-Tracking White balance mode, adjusts the white balance automati-
AWC : Auto White Control mode, which displays "PUSH SET → ADJ. STRAT".
R-B GAIN
Adjusts the phases of R (Red) and B (Blue) under AWC mode.
• To enhance blue: Decrease the value.
• To enhance red : Increase the value.
Setting values : 0 to 255
M-G GAIN
Adjusts the phases of M (Magenta) and G (Green) under AWC mode.
• To enhance green
• To enhance magenta : Increase the value.
Setting values : 0 to 255
FACTORY SETTINGS screen
This screen resets values to their factory settings.
Item
FACTORY
Resets all settings in the above menus to their initial factory settings. Pressing the
SETTINGS
SET button displays "EXECUTING" (2 sec. approx.) and resets the settings to the
factory settings.
CANCEL
CLEAR (W/O POS. TITLE) : Resets the settings to the initial, factory settings.
CLEAR (ALL)
E-28
Function & Setting
: for auto iris adjustment under standard conditions.
: for auto iris adjustment under slightly brighter conditions.
: for auto iris adjustment under slightly dimmer conditions.
Photometry area
Photometry area
OFF
AREA 1
cally according to the color temperature of the lighting conditions.
When ATW is set, "---" is displayed for the items "R-B GAIN" and "M-G
GAIN", so that the color phase adjustment cannot be carried out.
When the SET button is pressed, AWC is activated and the white balance
adjustment starts.
If the AWC is activated while the screen is B&W the LOW LIGHT ERROR
will be displayed. This is not abnormal.
: Decrease the value.
Function & Setting
: Does not alter current values.
However, the set positions, the setting data of each
position and the titles are not reset to the factory set-
tings.
: Resets all settings including titles and stored positions.
Photometry area
Photometry area
AREA 2
AREA 3
page 24) is set to ON, the item "BLC" is set to OFF and
Initial Value
Photometry area
AREA 4
Initial Value
–
AUTO
OFF
ATW
95