Changes: Manual for Sunways Solar Inverters NT 8000 / NT 10000
The Sunways Solar Inverters of the NT series have been internally optimised. This results in
changes compared to this manual.
Fixed voltage setting (page 103): The configuration of the fixed voltage switch no longer
needs to be set.
Country selection (page 104): The country no longer needs to be set as described in the
manual. It is pre configured at the plant depending on the country of delivery.
Technical Data (page 158)
DC Input
Rated DC power
Maximum DC current
Nominal DC voltage
MPP voltage range
Maximum voltage DC
Number of inputs per MPP
tracker
Number of MPP trackers
AC output
Rated AC output power
Maximum AC power
Nominal AC current
Maximum AC current
Nominal frequency
Frequency tolerance range
Grid voltage
AC voltage range
Distortion factor at Pn
SD130531A Version 08/08
NT 8000
8800 W
8,0 A per MPP input
1 x Tyco Solarlok
8000 W
8000 W
11,6 A per phase
15,0 A per phase
47,5 Hz...50,2 Hz (according to DIN VDE 0126 1 1)
20%...+15% (according to DIN VDE 0126 1 1)
NT 10000
11000 W
10,0 A per MPP input
400 V
350 V...750 V
850 V
3
10000 W
10000 W
14,5 A per phase
18,2 A per phase
50 Hz
400 V
< 3%