After the above procedure, press PP to send a command: the control unit activates closing to come into contact with the end
stop and then re-opens completely.

POWER ADJUSTMENT

Perform the impact tests and adjust the force levels of ZEN by means of the trimmer (detail 22 Fig. 14).
at the top of the door to dampen impact.
COUPLING TYPE RECEIVER mod. OC (optional)
The receivers are "self-learn" type and can memorise several codes on the same channel.
The functions of the two radio channels are:
Channel 1 Step/step
Channel 2 N.O.
To memorise the transmitters proceed as follows:
- Power up the control unit and wait for the receiver leds to turn off.
- Transmitter with remote control to be programmed.
The code memory can be reset if required, by pressing and holding P1 on the receiver for approx. 15 seconds until
all leds light up.
IMPORTANT RECOMMENDATIONS CONCERNING INSTALLATION
5) Analyse the hazards connected with the automation system and adopt the necessary safety and signalling devices accordingly.
7) Upon completion of the installation, test the safety, signalling and release devices of the automation system several times.