Measuring station
Malfunctions which may impair safety must not be generated in the training environment, and must be
eliminated immediately.
Wear personal protective equipment (safety goggles, safety shoes) when working on circuits.
Mechanical safety
Only reach into the setup when it is at a complete standstill.
Mount all of the components securely onto the slotted profile plate.
Limit switches may not be actuated frontally.
Risk of injury during troubleshooting!
Use a tool to actuate the limit switches, for example a screwdriver.
Set all components up so that activation of switches and disconnectors is not made difficult.
Adhere to the instructions regarding positioning of the components.
Electrical safety
Use extra-low voltage only (max. 24 V DC).
Only establish or interrupt electrical connections when there is no voltage present!
Use only connecting cables with safety plugs for electrical connections.
Pull the plug only when disconnecting connecting cables; never pull the cable.
Pneumatic safety
Do not exceed the maximum permissible pressure of 600 kPa (6 bar).
Do not switch on the compressed air until all tubing connections have been completed and secured.
Do not disconnect tubing while under pressure.
Risk of injury when switching compressed air on!
Cylinders may advance and retract automatically.
Danger of accident due to advancing cylinders!
Always position pneumatic cylinders so that the piston's working space is unobstructed
over the entire stroke range.
Make sure that the piston rod cannot collide with any rigid components of the setup.
Danger of accident due to tubing slipping off!
Use shortest possible tubing connections.
In the event that tubing slips off:
Switch compressed air supply off immediately.
Setting up the pneumatic circuit:
Connect the devices with plastic tubing with an outside diameter of 4 or 6 mm. Push the tubing into the
push-in connector as far as it will go.
Switch the compressed air supply off before dismantling the circuit.
Dismantling the pneumatic circuit:
Press the blue release ring down, after which the tubing can be pulled out.