Pointek CLS100 Quick Start Manual
Note:
Use Pointek CLS100 only in the manner outlined in this instruction manual.
For applications in areas classified as Hazardous, observe any restrictions according to
the relevant certificate.
Pointek CLS100 is a compact 2-wire capacitance switch for level detection in constricted
spaces, interfaces, solids, liquids, slurries, and foam. The stainless steel process
connection versions (7ML5501) have an effective process temperature range of -30 to
+100 °C (-22 to +212 °F) and the synthetic process connection version (7ML5610) has an
effective process temperature range of -10 to +100 °C (+14 to +212 °F).
Pointek CLS100 versions:
I I ntegral cable version with stainless steel process connection and probe options of
PPS or PVDF
E E nclosure version (thermoplastic polyester enclosure) with stainless steel process
connection in combination with a PPS or PVDF probe
E E nclosure version (thermoplastic polyester enclosure) with fully synthetic process
connection combined with a PPS probe
Features
NPT, R (BSPT), G (BSPP) process
connections
Corrosion resistant construction,
PPS, and 316L stainless steel
(optional PVDF wetted parts)
Non-polarized, solid-state switch or
relay output (enclosure version with
fully synthetic process connection
only)
Pointek CLS100 approval types:
Stainless steel process
connection (integral cable or
enclosure version) (7ML5501)
General: CE, CSA, FM
Marine: Lloyd's Register of
Shipping, categories ENV1, ENV2,
and ENV5
Dust Ignition Proof (barrier
required): CSA/FM Class II and III,
Div. 1, Groups E, F, G
Intrinsically Safe (barrier required):
CSA/FM Class I, II and III, Div. 1,
Groups A, B, C, D, E, F, G T4
ATEX II 1 GD 1/2GD EEx ia IIC T4 to
T6 T107 °C
Overfill protection: WHG (Germany)
C-TICK (Australia)
7ML19985QJ83
Applications
Liquids, slurries, powders, granules,
and solids
Foods and pharmaceuticals
Chemical and petrochemical
Hazardous areas
Fully synthetic process connection
(enclosure version only) (7ML5610)
General: CSA, FM
Marine: Lloyd's Register of Shipping,
categories ENV1, ENV2, and ENV5